Liquid Catalyst Boiler Oxygen
Scavenger
Description & Use
-
Catalyzed highly concentrated sulphite solution for faster
reaction.
-
Prevents corrosion in boilers and minimizes corrosion in
condensate and feed lines.
-
Cost-effective concentrate.
-
Can be
used in all boilers operating up to 16 bar.
-
Convenient liquid formulation suitable for automatic dosing.
Specification
-
Appearance : Pale liquid.
-
Odor
: Pungent, characteristic.
-
Specific Gravity : 1.22-1.30.
-
Flash
Point : Non-flammable.
-
pH
: 5 - 6.2.
-
Freeze
Point : 0oC (32oF).
(All
values approximate)
Dosage, Feeding & Control
Mercy Steam 6224
is normally fed continuously to the dearater or feed water
storage tank and maybe fit directly to the feed line
simultaneously with the scale inhibitor product.
Mercy Steam 6224
contains a blend of catalyzed sulphite and can be tested easily
to get a reserve of 30 ppm sulphite. A high feed temperature
value will make the dosage rate of this product very low.
The removal
of oxygen from boiler feedwater will reduce corrosion in all
areas of the steam system, including feedlines, boilers and the
condensate system.
Packaging
Mercy Steam 6224
is packaged in 32 kg and 256 kg plastic drums.
Safety & Handling
Do not take
internally. If ingested, drink at least two glasses of water
and get medical attention. Contact with eyes causes severe
irritation or burns. If eyes are contacted, immediately flush
with clear water for 15 minutes and get medical attention. For
skin contact, wash with soap and water.
|